Flammer Technologies
Sizing tools
Home › Rupture disc sizing
API RP 520 · ASME VIII · ISO 4126-6

Rupture Disc Sizing Calculator

Find the flow area and disc size for gas, steam or liquid relief. Try the quick estimate below, or open the full tool for back pressure, fire cases, drawings and a datasheet.

Quick estimate: gas service

Required flow area and disc size for a gas discharging to atmosphere.

Assumes: API 520 Part I coefficient-of-discharge method, Kd = 0.62, 10 % overpressure, ideal gas (Z = 1), discharge to atmosphere, critical flow.

Get the full datasheet →Free account. All fluid states, back pressure, drawings and PDF datasheet.

What the full rupture disc calculator does

How rupture disc sizing works

A rupture disc is sized so that, once it has burst, the opening passes the required relief flow without the vessel pressure rising above the limit set by the design code. For a gas in critical flow, API 520 Part I gives the required area as:

A = W / (C · Kd · P1) · √(T · Z / M)

where W is the mass flow, C a constant that depends on the gas, Kd the discharge coefficient, P1 the absolute relieving pressure, T the absolute temperature, Z the compressibility factor and M the molecular weight. The disc chosen is the next standard size whose flow area is at least A. The guide Rupture disc sizing to API 520 walks through every step with numbers.

Inputs you will need

InputGasSteamLiquid
Burst pressure and back pressureYesYesYes
Required flow (or the disc area, to find capacity)YesYesYes
Relieving temperatureYesFor superheatNo
Molecular weight, k and ZYes (auto-filled from the gas list)NoNo
Specific gravityNoNoYes

Common questions

Which standards does the rupture disc calculator follow?

API RP 520 Part I, ASME Section VIII Division 1 and ISO 4126-6. You choose the design code and the tool applies its overpressure rules and reports against it.

What information do I need to size a rupture disc?

The burst pressure, the relieving temperature, the fluid (gas, steam or liquid) and the flow the disc must pass. For a gas the tool also needs the molecular weight and the ratio of specific heats, which it fills in when you pick the gas from the list.

What discharge coefficient is used?

Kd = 0.62 for gas and steam and 0.65 for liquid by default, as used in the coefficient-of-discharge method. You can enter a certified value for a specific disc.

Is the quick estimate enough to order a disc?

No. It covers one common case: a gas discharging to atmosphere at 10 % overpressure. Back pressure, steam, liquids, fire cases and the choice of disc model are handled in the full tool, and the final selection should be confirmed with Flammer.

Do the full calculation, free

Rupture disc, safety valve and explosion vent sizing with a live drawing, saved projects, Excel import and a printable datasheet.

Open the sizing tool →